Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta ortop. bras ; 30(spe1): e248982, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1383439

RESUMO

ABSTRACT Objective: To evaluate the effect of 3d printed models on surgical pre-operative planning of complex spinal deformities. Methods: In our study, five orthopedic surgeons made surgical planning of 5 patients with severe spinal deformity in three conditions: X-ray with computer tomography (X-ray-CT), 3D-computed tomography (3dCT), and 3d printed spine models. Operation plans were examined according to the level and number of instrumentations, osteotomy level, and time required for decision-making. Results: X-ray-CT, 3dCT, and 3d modeling methods were compared, and no statistically significant difference was observed in the number of screws and osteotomy score to be used in operation. The time required for decision ranking is 3d Model, 3d CT, and Xray-CT. Conclusions: 3d printed models do not influence the operative plan significantly; however, it reduces surgical planning time at pre-op duration, and those models gave some opportunities to practice with implants on a patient's 3d spine model. Level of Evidence III; Diagnostic Studies - Investigating a Diagnostic Test .


RESUMO Objetivo: Avaliar o efeito de modelos 3D impressos no planejamento pré-operatório cirúrgico de deformidades complexas da coluna vertebral. Métodos: Em nosso estudo, 5 cirurgiões ortopédicos fizeram o planejamento cirúrgico de 5 pacientes com deformidade espinhal grave em três condições: raio-X com tomografia computadorizada (raio X-CT), tomografia computadorizada com reconstrução 3D (3dCT) e modelo de coluna vertebral impressa (modelo 3d). Os planos de operação foram examinados de acordo com o nível e número de instrumentos, nível de osteotomia e tempo necessário para a tomada de decisão. Resultados: Foram comparados os métodos de modelagem de raio X-CT, 3dCT e modelo 3d e nenhuma diferença estatisticamente significativa foi observada no número de parafusos e escore de osteotomia a serem utilizados na operação. O ranking do tempo necessário para a tomada de decisão foi de modelo 3d, 3d CT e raio X-CT. Conclusões: Os modelos impressos em 3d não influenciam significativamente o plano operatório, porém reduzem o tempo de planejamento cirúrgico no pré-operatório e esses modelos deram algumas oportunidades de praticar com implantes no modelo de coluna 3d do paciente. Nível de evidência III; Estudos de Diagnóstico - Investigando um Teste de Diagnóstico .

2.
ImplantNews ; 10(6a): 179-184, 2013. ilus, tab
Artigo em Português | LILACS | ID: lil-761244

RESUMO

O presente estudo in vivo propôs avaliar a precisão de instalação de 23 implantes sem retalhos empregando guias cirúrgicos obtidos por estereolitografia em quatro pacientes com maxilas totalmente desdentadas. Após duplo escaneamento com tomografia computadorizada tipo cone-beam, o planejamento pré-cirúrgico foi realizado com o programa Procera. Depois da cirurgia, realizou-se a comparação entre as posições dos implantes planejados e executados através de tomografia computadorizada pós-operatória. Para comparação da posição e dos longos eixos das imagens dos implantes foram eleitos três pontos em cada implante planejado e executado: no centro do limite coronário (D1), no centro da porção central (D2), no centro do limite apical (D3). Assim, as distâncias e o ângulo (A1) formado entre os longos eixos dos implantes planejados e executados foram numericamente calculados. De acordo com a análise tomográfica, os implantes executados em relação aos implantes planejados apresentaram desvios médios de 0,72 mm para a posição D1; 0,98 mm para a posição D2; 1,45 mm para a posição D3; 1,92 graus para o ângulo A1. Concluiu-se que houve desempenho adequado para a utilização de protocolos de cirurgia guiada baseados no método empregado em associação com guias cirúrgicos produzidos pelo processo de estereolitografia. A transferência do planejamento protético-cirúrgico para o campo operatório foi considerada satisfatória, visto que viabilizou a instalação de implantes dentários nas situações propostas...


The aim of this in vivo study was to evaluate the placement accuracy of 23 dental implants with fl apless surgery using stereolithographic guides in four completely edentulous maxillary patients. After double scanning with cone beam computerized tomography (CBCT), the presurgical planning was performed using appropriate software (Procera). After surgery, executed and planned implant positions were compared using CBCT superimposing. Measurements were made at the center of three pre-selected points: coronal (D1), central (D2), and apical (D3) portions. Thus, the distances among points and the angle (A1) formed between the long axes of the planned/executed implants were calculated. Mean deviations were as the following: 0.72 mm at D1, 0.98 mm at D2, and 1.45 mm at D3 positions. The mean angular deviaton (A1) was 1.92 degrees. It was concluded that there was adequate performance with surgical guides produced by stereolithographic process. The transfer of prosthetic-surgical planning for the surgical area was considered satisfactory, since it allowed for implant placement in proposed situations...


Assuntos
Humanos , Tomografia Computadorizada de Feixe Cônico , Implantes Dentários , Estereotipagem , Cirurgia Assistida por Computador
3.
Arq. neuropsiquiatr ; 69(4): 693-698, Aug. 2011. ilus
Artigo em Inglês | LILACS | ID: lil-596839

RESUMO

The advent of modern image-guided surgery has revolutionized depth electrode implantation techniques. Stereoelectroencephalography (SEEG), introduced by Talairach in the 1950s, is an invasive method for three-dimensional analysis on the epileptogenic zone based on the technique of intracranial implantation of depth electrodes. The aim of this article is to discuss the principles of SEEG and their evolution from the Talairach era to the image-guided surgery of today, along with future prospects. Although the general principles of SEEG have remained intact over the years, the implantation of depth electrodes, i.e. the surgical technique that enables this method, has undergone tremendous evolution over the last three decades, due the advent of modern imaging techniques, computer systems and new stereotactic techniques. The use of robotic systems, the constant evolution of imaging and computing techniques and the use of depth electrodes together with microdialysis probes will open up enormous prospects for applying depth electrodes and SEEG both for investigative use and for therapeutic use. Brain stimulation of deep targets and the construction of "smart" electrodes may, in the near future, increase the need to use this method.


O advento das modernas técnicas de cirurgia guiadas por imagem revolucionaram a técnica de implantação dos eletrodos de profundidade (EP). A estereoeletroencefalografia (E-EEG), conforme introduzida na década de 50 por Talairach, é um método invasivo de análise tridimensional da zona epilpeptogênica, baseado na técnica de implantação intracraniana de EP. O objetivo deste artigo é discutir os princípios da E-EEG e sua evolução, desde a era Talairach até a era atual, da cirurgia guiada por imagem, e suas perspectivas futuras. Embora os princípios gerais da E-EEG tenham permanecidos intactos ao longo dos anos, a implantação de EP, que é a técnica cirúrgica que viabiliza este método, sofreu grande evolução ao longo das últimas três décadas devido ao advento das modernas técnicas de imagem, de sistemas de computação e das novas técnicas estereotáxicas. O uso de sistemas robotizados, a evolução constante das técnicas de imagem e computação e a utilização de EP com sondas para micro diálise associados a si, abre no futuro uma enorme perspectiva para a aplicação dos EP e da E-EEG, tanto para uso investigativo como terapêutico. A estimulação cerebral de alvos profundos e a fabricação de eletrodos "inteligentes", poderão incrementar, num futuro próximo, a necessidade do uso deste método.


Assuntos
Humanos , Eletrodos Implantados , Eletroencefalografia/métodos , Epilepsia/cirurgia , Cirurgia Assistida por Computador , Monitorização Intraoperatória , Técnicas Estereotáxicas
4.
J. epilepsy clin. neurophysiol ; 15(4): 178-183, dez. 2009. ilus, tab
Artigo em Português | LILACS | ID: lil-545424

RESUMO

INTRODUÇÃO: A estereoeletroencefalografia (E-EEG), conforme introduzida na década de 50 por Talairach, é um método invasivo de análise tridimensional da zona epilpeptogênica, baseado na técnica de implantação intracraniana de eletrodos de profundidade (EP). O advento das modernas técnicas de cirurgia guiadas por imagem revolucionaram a técnica de implantação dos EP. OBJETIVO: O objetivo deste artigo é discutir os princípios da E-EEG e sua evolução, desde a era Talairach até a era atual, da cirurgia guiada por imagem, e suas perspectivas futuras. CONCLUSÕES: Embora os princípios gerais da E-EEG tenham permanecidos intactos ao longo dos anos, a implantação de EP, que é a técnica cirúrgica que viabiliza este método, sofreu uma tremenda evolução ao longo das últimas três décadas devido ao advento das modernas técnicas de imagem, de sistemas de computação e das novas técnicas estereotáxicas. O uso de sistemas robotizados, a evolução constante das técnicas de imagem e computação e a utilização de EP com sondas para micro diálise associados a si, abre no futuro uma enorme perspectiva para a aplicação dos EP e da E-EEG, tanto para uso investigativo como terapêutico. A descoberta de novos alvos, em localizações profundas e a fabricação de eletrodos "inteligentes", poderá incrementar, num futuro próximo, a necessidade do uso deste método.


INTRODUCTION: The stereoelectroencephalography (SEEG), introduced by Talairach in 50', is an invasive method of tridimensional analysis of epileptogenic zone based on the intracranial placement of depth electrodes (DE). The advent of modern imaging guided surgery had a tremendous impact in DE implantation techniques. OBJETIVE: The aim of this article is to discuss the main principles of SEEG and its evolution along the years since Talairach era until the imaging guide surgery era, with its new perspectives. CONCLUSIONS: Although the main principles of SEEG have remained intact, the placement of depth electrodes (DE) which is the surgical technique that supports this method has suffered a tremendous evolution along the last three decades due the advent of the modern imaging, the computer systems and the new stereotactic techniques. The use of robotic, the new imaging and computed systems and the use of probes of micro dialise adaptated to EP opened a tremendous perspective to DE and SEEG application as an investigative and therapeutical method. The discovery of new targets in deep brain localization and the manufacturing of "smart" DE, can increment, in a near future, the number of indications to this method.


Assuntos
Humanos , Cirurgia Assistida por Computador , Eletrodos , Epilepsia/cirurgia
5.
ACM arq. catarin. med ; 32(supl.1): 282-285, out. 2003. ilus
Artigo em Português | LILACS | ID: lil-517790

RESUMO

Descrição de caso de tumor orbital extraconal subperiostal superior, produzindo proptose e desvio caudal do globo ocular, sem interferência nos movimentos oculares, com dezoito meses de evolução, em paciente feminina, com 39 anos de idade. Ausência de alterações ósseas, ao R, TC e RM, demonstrava presença de massa tumoral medindo 3 x 1,5 cm, extraconal, sobre o músculo elevador da pálpebra e sob o periósteo, no segmento orbital superior direito. Cirurgia programada, com sistema de navegação (cirurgia guiada por imagem) com superposição de imagens, de TC e RM. Ressecção completa da lesão, sem comprometimento neurológico ou funcional do globo, e excelente resultado estético.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Descompressão Cirúrgica , Cirurgia Assistida por Computador , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/normas , Descompressão Cirúrgica/reabilitação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...